Step #1

The Hydro-Safe filter cartridge is pleated for greater surface area using a micro-fiber, rated at 0.2 micron.  This unique filter media is certified under NSF/ANSI Standard 53 for cysts reduction and has the capacity to remove sub-micron particles and harmful microorganisms with very little pressure drop or flow restriction.

This is an important step in the triple-treat process.

Step#2 Carbon Treatment

An exceptionally fine activated carbon powder is added to the sub micron filter fiber using an electrostatic bonding process.  Activated carbon provides a secondary treatment process to remove chlorine, taste and odors.




tank

Step #3
uv

During the final process, water flows into a stainless steel reaction chamber where it is exposed to a 254 nanometer UV lamp.  Inside this chamber bacteria, viruses and other harmful microorganisms are destroyed to provide disintection withou the use of chemicals.

 

BioVir

Independant lab validated
Hydro-Safe systems have been tested by Bio-Vir labs to validate performance. Test results confirm bacteria is reduced by 99.9%.
(E-coli bacteria used for tests.)

note
Cartridges have double o-rings for superior sealing and performance.

Specifications (Model HSFS)

Flow rate (max).
14 GPM
Voltage (lamp)
110 Volts
Cartridge capacity
(Gals./average use)
200,000
gallons
UV dose rate (mJ/cm2)
40,000+
Bacteria reduction*
99.9%
*E-Coli used for tests with cartridge in place.